Circuit Breakers

    Inventory #

  AB5430

5 VHK 250

by

ABB

Air Circuit Breaker

1200 amps

5000 volts

Medium Voltage

all specifications...
  • 5 VHK 250 available as-is,
    or remanufactured
  • Remanufactured breaker includes
    1 Year Parts & Labor Warranty
  • Large stock of 5 VHK 250 Replacement Parts
Product Photos
011 nameplate 012 013 014 015

Current Condition

This photo shows a similar circuit breaker to AB5430, after it had undergone remanufacturing by
RESA Power. Actual photos of this 5 VHK 250 Air Breaker in its current condition are shown above.

Detailed Specs
General Specifications

Catalog #: 5 VHK 250

Type: Air Breaker

Manufacturer: ABB

Manufactured Date: 07/01/91

Serial #: PO4036A1-010701


Ratings

Frame Current: 1200 amps

Voltage: 5000 volts

Electric operation

Drawout mounting


Engineering Specifications

Trip Volts: 125VDC

Close Volts: 125VDC

Charge Volts: 125VDC


Written Detailed Specification

ABB 5 VHK 250 Drawout mounted Air Circuit Breaker, Medium Voltage, 1200 Amps, 5000 Volts, Electric operation.


Warranty

RESA Power warranties this refurbished ABB 5 VHK 250 circuit breaker for one year, including all labor, freight and materials required to return it to operational standards. RESA Power guarantees this breaker will operate to your satisfaction given competent supervision and normal load and usage conditions. Any repairs performed without the express written permission of RESA Power Inc. shall invalidate this warranty. RESA Power shall not be liable to the customer, or to any other person, for consequential damages, lost profits or other kinds of damages arising out of the sale or use of this circuit breaker.


The ABB 5 VHK 250 from RESA Power

All ABB 5 VHK 250 Air Breakers can be purchased as remanufactured to factory standards (please see 5 VHK 250 factory remanufacturing specification). You can also order your ABB 5 VHK 250 Air Breaker wired to your specified wiring diagrams. We also carry a large stock of replacement parts for the ABB 5 VHK 250 Air Breaker. Call one of our sales consultants today.

Remanufacturing
Circuit Breaker Remanufacturing
Circuit Breaker Remanufacturing

At RESA Power, we don’t just rebuild Air Breakers, we remanufacture them. All of our remanufactured circuit breakers conform to NETA and ANSI C37 specifications, and all tolerances are checked to meet or exceed the original manufacturer’s specifications. Here’s how we will remanufacture this ABB 5 VHK 250 for you:

Inspection and Initial Testing

We’ll start with an initial inspection and test of this Air Breaker. We first want to check its mechanical and electrical operation. We’ll then perform a “Ductor” test, a “Megger” test, and several other tests to determine our starting point. (See “Testing Procedures” below for further description.)

During our initial testing, we’ll take note of any wiring, taping, or heat shrinking that shows any signs of deterioration. We’ll also note any springs showing signs of distortion, rust, brittleness, or improper compression. Noted items will be replaced later using equivalent or superior components.

Disassembly, Cleaning, and Replacement

All of our remanufactured circuit breakers are dismantled down to the last moving part:

  • Conductive parts are bead blasted as needed and cleaned using a vibratory cleaner.
  • Plated parts showing signs of peeling are replated or replaced.
  • Insulated parts and pole pieces are solvent cleaned to be free of silicone, oil, paint and moisture.
  • Frame parts and mechanism parts are aluminum oxide blasted and then repainted or replated.
  • All standard hardware is replaced with new hardware.
  • All pins are replated.
  • Roller and needle bearings are lubricated. (Nylon sleeve bearings do not require lubrication).
  • All springs are either replated or replaced.
  • Control wiring is cleaned or replaced as necessary.
  • Toggle switches, motor cut-off switches and relays are cleaned or replaced with identical or equivalent devices. Voltage and amperage ratings will always meet or exceed original specifications.

Reassembly and Final Testing

Now that the circuit breaker has been torn down with all of its components cleaned, refurbished or replaced, it’s time to put it all back together. RESA Power follows a meticulous quality control procedure during reassembly to ensure years of trouble-free operation. Breakers are reassembled to the original factory specification as follows:

Circuit Breaker Remanufacturing
  • Frame parts are reassembled and aligned.
  • Contact assemblies are adjusted to the manufacture's guidelines.
  • Current-carrying parts are reassembled and torqued to the manufacturer's or NETA standards.
  • New retainer pins or clips are carefully installed and checked.
  • Electrical devices and wiring harness are re-installed on the breaker and checked per factory or customer's wiring specifications.

Upon completion of reassembly, the now completely remanufactured circuit breaker is retested and certified by a quality control engineer. The rebuilt circuit breaker will be delivered to you with a Job Packet containing an Initial Inspection Report, a Quality Control Checklist, and a Final Test Report. These reports include all pertinent information to ensure that you are receiving a product of the highest quality.


Testing Procedures

"Ductor" Test

The Digital Low Resistance Ohmmeter (“Ductor”) uses dual spike probes to measure the resistance of the current carrying path of the entire phase. This test includes as much of the path as practical for each pole, ensuring that the entire pole (not just the contacts) has a low resistance.

“Megger” Test

The insulation of the circuit breaker is tested utilizing a 1000 volt megohmmeter (“Megger”). The breaker is tested in the closed position because of the additional stress placed on the insulators due to spring tension. The insulation is tested between phase-to-phase and phase-to-ground. With the breaker open, the breaker is tested from line-side to load-side of each pole, verifying insulation between the source and the load. The lowest reading of each phase is recorded. RESA Power maintains a standard requirement of a minimum of 500 megohms, ten times NETA minimum requirement.

High Current Primary Injection Test

The high current test is performed using a low voltage (usually less than 12 VAC) high current test set. Each phase or pole is tested for every trip function provided on the trip unit. The test is conducted in the following order to standardize results:

  • Long time (300% of pick-up current)
  • Short time (150% of pick-up current)
  • Ground time (150% of pick-up current)
  • Instantaneous1 (Determines the pick-up current)

1 Instantaneous is not a time test like the others. Therefore the test uses a short pulse of current and the short time functions are overridden or adjusted out of range of the instantaneous setting.

Control Circuitry Test

The control diagram of the circuit breaker is verified against your drawing or the manufacturer’s diagram. The circuit breaker is electrically operated using a variable power supply to check the pick-up voltage of the trip coil, under-voltage coil, and the closing coil. The maximum voltage limit of the close coil is also tested so it will still close and latch.


Warranty

RESA Power warranties this rebuilt ABB 5 VHK 250 circuit breaker for one year, including all labor, freight and materials required to return it to operational standards. RESA Power guarantees this breaker will operate to your satisfaction given competent supervision and normal load and usage conditions. Any repairs performed without the express written permission of RESA Power Inc. shall invalidate this warranty. RESA Power shall not be liable to the customer, or to any other person, for consequential damages, lost profits or other kinds of damages arising out of the sale or use of this circuit breaker.

Other Products
Similar Products to AB5430 (5 VHK 250)
Catalog Number Manufacturer Type Frame Current Voltage
5 VHK 250 ABB Air Breaker 1200 amps 5000 volts
5 VHK 250 ABB Air Breaker 1200 amps 5000 volts
5 VHK 250 ABB Air Breaker 1200 amps 5000 volts
5 VHK 250 ABB Air Breaker 1200 amps 5000 volts
5 VHK 250 ABB Air Breaker 1200 amps 5000 volts
5 VHK-X 250 ABB Air Breaker 1200 amps 5000 volts
K 800M ABB Air Breaker 800 amps 600 volts
K-600 ABB Air Breaker 600 amps 600 volts
K-800 ABB Air Breaker 600 amps 600 volts
MBE 8 ABB Air Breaker 800 amps 600 volts
MBE 8 ABB Air Breaker 800 amps 600 volts
SACE-E6H-A-40 ABB Air Breaker 4000 amps 600 volts